Detecting Blood Disorders Made Easier with High-Performance Graphene-Based Biosensors

Chung Ang University
5 min readJan 27, 2021

Scientists design a high-performance laser-printed graphene-electrode biosensor, with potential for point-of-care diagnostic applications

Thrombin, found in increased concentrations in the blood under abnormal conditions, is a crucial indicator of blood disorders. Aptamer-based electrochemical biosensors, known for their high sensitivity and low detection limit, are best suited to detect low concentrations of thrombin. Scientists in Germany and Korea took these biosensors to the next level in their new “label-free” design consisting of laser-induced graphene (a highly porous material), thus paving the way for their easy application in point-of-care diagnostics.

Scientists design a high-performance laser-printed graphene-electrode biosensor, with potential for point-of-care diagnostic
A “label-free” biosensor to detect small concentrations of disease markers such as thrombin is essential to developing point-of-care diagnostics in the future | Photo courtesy: Amornthep Srina from Pexels

Thrombin is an enzyme that plays a vital role in wound healing by helping retain blood within the damaged blood vessel — a process known as hemostasis. What is more interesting to biologists, however, is that thrombin is found in increased concentrations under abnormal conditions, and thus can be used to diagnose and monitor blood disorders and malignancies. Thus, it is crucial to detect even minute concentrations of thrombin in the blood. Now, a team of researchers has devised a novel biosensor for accurately detecting minute amounts of thrombin in the blood, thereby promising to revolutionize the field of blood disorder diagnostics. Read on to know how!

The detection of biomarkers is usually accomplished by a “biosensor,” which consists of a biorecognition element (receptor) that interacts with the target molecule and a transducer that converts the bio-recognition information into a measurable signal. While antibodies (proteins with the ability to detect and bind to specific molecules) have been traditionally used as a biorecognition element, they are unstable and difficult to synthesize. A better alternative to them are “aptamers” — nucleic acid-based molecules that can bind to a specific target molecule and are more stable than antibodies. Moreover, aptamer-based electrochemical biosensors are known to have high sensitivity and low limits of detection, making them ideal to detect small concentrations of biomarkers like thrombin. The only problem is that biomarkers are often hard to detect unless tagged with a “label” (such as an enzyme or a fluorescent molecule). To make the process of detection easier and cheaper, skipping this “labeling” step is crucial.

To achieve this, the aforementioned team of scientists, from University of Regensburg, Germany, and Chung-Ang University, Korea, designed a novel aptamer-based biosensor consisting of a “laser-induced graphene” (LIG), a material that is highly porous and can be fashioned in an interlocking manner to form what are called “interdigitated electrodes.” Associate Professor Min-Ho Lee from Chung-Ang University, one of the lead scientists on this study explains, “LIG combines the high electrical conductivity of graphene with an ultra-easy fabrication procedure that simply requires a CO2 laser printer. In addition, the high porosity and the interlocking design enhance the biosensor’s sensitivity.

The newly designed biosensor is based on “capacitive” sensing, which relies on direct binding of the sensor to the target molecule. In an earlier paper by the same team, scientists had found, based on electrochemical impedance spectroscopy studies, that LIG electrodes exhibit high performance at low frequencies. In their latest paper published in Biosensors and Bioelectronics, the team used this knowledge to optimize their biosensor and accordingly recorded its response at a frequency of 0.5 Hz (or half cycles per second), for different concentrations of thrombin in buffer and serum samples. They measured its sensitivity and limit of detection as a function of electrode size and “labeling” done with liposomes and polymer nanoparticles.

The team found that the LIG biosensor could reliably detect thrombin concentrations varying over 5 orders of magnitude with an ultralow limit of detection and showed little change in performance with the electrode size. In addition, they found that the label-free detection worked extremely well with the additional nanoparticle labels, only minimally increasing the sensitivity or lowering the limit of detection. The scientists attributed this observation to the high porosity of the electrodes dominating the capacitive response of the sensor. Moreover, the sensor performance exhibited good reproducibility, repeatability, and long-term stability (>7 weeks), demonstrating its robustness.

With such encouraging results, the scientists are excited about the future prospects of LIG-based aptamer biosensors for the detection of thrombin and other useful biomarkers. Dr. Lee optimistically concludes, “The ease of production, simplicity of modification, and superior performance even in a label-free format suggest that LIG biosensors could be considered for point-of-care diagnostics in the near future. With the combination of aptamers and our new graphene-based electrode, commercialization of electrochemistry immunoassays can be possible in the next 5–10 years.

Reference

Authors: Ajay Kumar Yagati (1,2), Arne Behrent (1), Sebastian Beck (3), Simone Rink (1), Achim M. Goepferich (3), Junhong Min (2), Min-Ho Lee (2), and Antje J. Baeumner (1)

Title of original paper: Laser-induced graphene interdigitated electrodes for label-free or nanolabel-enhanced highly sensitive capacitive aptamer-based biosensors

Journal: Biosensors and Bioelectronics

DOI: 10.1016/j.bios.2020.112272

Affiliations:

(1) Institute of Analytical Chemistry, Chemo-and Biosensors, Faculty of Chemistry and Pharmacy, University of Regensburg

(2) School of Integrative Engineering, Chung-Ang University

(3) Department of Pharmaceutical Technology, Faculty of Chemistry and Pharmacy, University of Regensburg

About Chung-Ang University

Chung-Ang University is a private comprehensive research university located in Seoul, South Korea. It was started as a kindergarten in 1918 and attained university status in 1953. It is fully accredited by the Ministry of Education of Korea. Chung-Ang University conducts research activities under the slogan of “Justice and Truth.” Its new vision for completing 100 years is “The Global Creative Leader.” Chung-Ang University offers undergraduate, postgraduate, and doctoral programs, which encompass a law school, management program, and medical school; it has 16 undergraduate and graduate schools each. Chung-Ang University’s culture and arts programs are considered the best in Korea.
Website: https://neweng.cau.ac.kr/index.do

About Dr. Min-Ho Lee and Dr. Junghong Min

Dr. Min-Ho Lee is an Associate Professor of Integrative Engineering at Chung-Ang University. His group is currently involved in developing approaches to measure multiple biomarkers through highly sensitive sensors. The group is also developing nanocomplexes for in vivo technology for the detection of pandemic contagious diseases. Before coming to Chung-Ang University, he was team leader of Medical IT center at Korea Electronics Technology Institute. Prof Lee received a PhD in Bioengineering from Rice University in 2006.

Dr. Junghong Min specialized in sensor design and nanomaterial application in advanced biotechnology and biochemical engineering. His group is currently working for molecular diagnostics for the detection of pathogen from clinical samples. He obtained PhD from Sogang University, South Korea, in 1998). He was a postdoctoral fellow at Korea University, South Korea, before joining Cornell University, United States (2000–2002). He worked for Innovative Biotechnologies in Grand Island, New York, as a senior scientist (2002–2003) before being a project leader in Samsung Group (South Korea, 2003). Since 2007, he was Associate Professor at the Gachon Bionano Research Institute, Gachon University (South Korea). He is currently a Professor at the School of Integrative Engineering, Chung-Ang University.

--

--

Chung Ang University

Chung-Ang University is a private comprehensive research university located in Seoul, South Korea. Website: https://neweng.cau.ac.kr/index.do